Alternative Power Flow Solutions
Slides from the Texas A&M Smart Grid Center webinar entitled “All About Power Flow Alternative Solutions Including How to Avoid Them”, delivered on September 3, 2025, may be accessed here. Alternative power flow solutions consist of those solutions that satisfy the non-linear power flow equations but do not represent stable operating points that would occur […]
Tags: Presentation,Simulator,Tutorial
September 3, 2025
Phase Shift Groups
In three-phase power systems, transformers with wye-connected windings on one side and delta-connected windings on the other are commonplace, as are three-winding transformers with a combination of wye and delta-connected windings. Such connections introduce phases shifts with multiples of 30°. In a standard (positive sequence) power flow these phase shifts need not be modeled; however, […]
Tags: Documentation,Fault Analysis,GIC,Presentation,Simulator
August 25, 2025
Regions in PowerWorld Simulator
The “Region” data structure, introduced with PowerWorld Simulator version 24, provides a way to group power system elements by geographic regions. A Region is defined as a polygon with latitude and longitude coordinates of its vertices. Regions may be loaded from shapefiles or auxiliary (*.aux) files, or defined graphically in PowerWorld Simulator. They may also […]
Tags: Documentation,How-to,Presentation,Product,Simulator
May 21, 2025
PowerWorld Simulator Integration with EPRI GICHarm
Beginning with version 24, PowerWorld Simulator’s GIC add-on is integrated with the Electric Power Research Institute’s (EPRI) GICHarm tool. The latter performs harmonic analysis on grid connected devices such as capacitor banks to determine if expected geomagnetic induced currents (GICs) could cause them to trip. This integration enables an iterative analysis, summarized by: Using an […]
Tags: GIC,Presentation,Simulator
January 27, 2025
Extension of Full Topology Models in PowerWorld Simulator Version 24
This is the abstract and a link to the presentation associated with the PowerWorld Corporation webinar of Wednesday September 18, 2024. Link to Presentation: Extension of Full Topology Modeling in Simulator Version 24 Title: Extension of Full Topology Modeling in Simulator Version 24 Abstract: PowerWorld Simulator introduced Integrated Topology Processing (ITP add-on) in 2008 to […]
Tags: Integrated Topology Processing,Presentation,Product,Simulator
September 9, 2024
Synchronous Machine Theory: New GENQEC Model
PowerWorld Director of Software Development gave a presentation at the WECC MVWG meeting in Salt Lake City on November 21, 2019. This presentations gives a very detailed theoretical look at where the synchronous machine numerical model comes from. Synchronous Machines Theory The presentation was given to provide background on where the need for a new […]
Tags: FAQ,Presentation,Product,Simulator,Transient Stability
November 20, 2019
Voltage Setpoint Tolerance
This article discusses a new feature that will be available in PowerWorld Simulator 21 when it released in 2019. If you are a customer of PowerWorld Simulator who is interested in testing the feature before Simulator 21 is released, please contact PowerWorld Corporation at info@powerworld.com. PowerWorld Simulator 21 will have a new field associated with […]
Tags: Presentation,Simulator,Technical Papers
January 30, 2019
Renewable Generators: Voltage Droop Control with Deadband in Power Flow Solution
This article discusses a new feature that will be available in PowerWorld Simulator 21 when it released in 2019. If you are a customer of PowerWorld Simulator who is interested in testing the feature before Simulator 21 is released, please contact PowerWorld Corporation at info@powerworld.com. Presentation on Voltage Droop Control with Deadband White Paper on […]
Tags: Presentation,Simulator,Technical Papers
October 24, 2018
Improved Synchronous Machine Model GENTPW
Presentation on GENTPW Model White Paper on GENTPW Model PowerWorld Corporation has developed a new synchronous machine model named GENTPW. This model has been implemented in PowerWorld Simulator Version 20 and is available now. This model extends enhancements made in the GENTPF/GENTPJ which more accurately represents the effect of saturation on the machine during steady […]
Tags: Presentation,Simulator,Technical Papers,Transient Stability
October 24, 2018
New Feature: Data Check
A new feature was added to PowerWorld Simulator in the April 9, 2018 patch of Simulator 20 called “Data Checks”. Data checks grew out of work that PowerWorld customers Jonathan Young (Columbia Grid) and John Gross (Avista Utilities) performed building on PowerWorld Simulator’s features of Advanced Filters, Calculated Fields, Dynamic Formatting, Expression and String Expressions. […]
Tags: How-to,Presentation,Simulator
August 3, 2018