Knowledge Base

Accessing Simulator Fields in SimAuto

You can access just about any value in Simulator in SimAuto with the correct object and field name. The easiest way to find the object and field names is through the Model Explorer. First, find and add the field you’re interested in to the Model Explorer. You can do this a couple of different ways, […]

Tags:

May 23, 2025

Regions in PowerWorld Simulator

The “Region” data structure, introduced with PowerWorld Simulator version 24, provides a way to group power system elements by geographic regions. A Region is defined as a polygon with latitude and longitude coordinates of its vertices. Regions may be loaded from shapefiles or auxiliary (*.aux) files, or defined graphically in PowerWorld Simulator. They may also […]

Tags: ,,,,

May 21, 2025

User Defined Model Documentation

Sample Files and Code For the Basic User: Sample DLLs and Test Case for Exciter, Governor, Machine, and Stabilizer For the Advanced Developer: GitHub Repository [recommended to Fork and continue your custom development] Has 64 bit build configured for C++ projects in Visual Studio 2019 Sample code projects for Exciter, Governor, Machine, Stabilizer, and Load […]

Tags: ,,,

March 13, 2025

PowerWorld Simulator Integration with EPRI GICHarm

Beginning with version 24, PowerWorld Simulator’s GIC add-on is integrated with the Electric Power Research Institute’s (EPRI) GICHarm tool. The latter performs harmonic analysis on grid connected devices such as capacitor banks to determine if expected geomagnetic induced currents (GICs) could cause them to trip. This integration enables an iterative analysis, summarized by: Using an […]

Tags: ,,

January 27, 2025

May 2024 GMD Event (Gannon Storm)

Below are visualizations and power flow simulations of the North American geomagnetic disturbance of May 10-12, 2024 (Gannon Storm). The simulations utilize surface electric field models developed by NOAA Space Weather Prediction Center with Empirical Magnetotelluric Transfer Functions (EMTF), which incorporate the full 3D effects of Earth conductivity structures. Surface Electric Field only (CONUS) Eastern […]

Tags: ,

September 25, 2024

Extension of Full Topology Models in PowerWorld Simulator Version 24

This is the abstract and a link to the presentation associated with the PowerWorld Corporation webinar of Wednesday September 18, 2024. Link to Presentation: Extension of Full Topology Modeling in Simulator Version 24 Title: Extension of Full Topology Modeling in Simulator Version 24 Abstract: PowerWorld Simulator introduced Integrated Topology Processing (ITP add-on) in 2008 to […]

Tags: ,,,

September 9, 2024

Generic Excitation Limiter Implementation

Type C excitation system transient stability models, as per IEEE standard 421.5-2016, have the ability to allow limiters to be added at one of multiple points within the model. The excitation limiters models also allow their own parameters to be modified, in order for them to be compatible with the exciter model that is in […]

Tags: ,,

May 12, 2024

Time-Step Weather Example

This example shows how historic and forecast ERA5 weather files can be loaded into PowerWorld Simulator and be used to determine the Max MW capability of wind and solar generation. Features such as contouring and geographic data views (GDV) are also applied to enhance visualization and interpretation. The files may be downloaded here. Here is […]

Tags: ,,

February 20, 2024

Simple Weather Example

This example introduces the basic functionality of PowerWorld Simulator’s weather integration capability and how other features, such as contouring and geographic data views (GDV), can enhance visualization and interpretation of how the weather can impact wind and solar generation. The files may be downloaded here. To apply the weather data and visualize results: Open the […]

Tags: ,,

February 12, 2024

Power Transfer Limit Exceeded by OPF

The Optimal Power Flow (OPF) solution involves iteration between a linear program (LP) to adjust controls (usually generation) and a non-linear power flow. If an AC OPF is performed over a very large Area (or Super Area), the LP may attempt to dispatch generators in a manner that exceeds voltage stability margins (PV) or maximum […]

Tags: ,,

October 17, 2023