Knowledge Base

Earth Resistivity Model for GIC Calculations

Updated February 8, 2022 with versions that do not contain dashes in the region set names PowerWorld Simulator GIC can automatically incorporate scaling factors for geomagnetic latitude and earth resistivity according to NERC TPL-007-2 – Transmission System Planned Performance for Geomagnetic Disturbance Events (October 2017). The earth resistivity models must be loaded from an auxiliary file. […]

Tags: ,,

January 31, 2018

EMP Simulation Example

PowerWorld Simulator version 20 includes the ability to analyze the E3 effects of a high-altitude electromagnetic pulse (HEMP) attack on the power system. Algorithms are based on public Oak Ridge National Laboratory research. To perform a sample analysis: Download this file. Extract the contents and open TX2000.pwb with PowerWorld Simulator (version 20 or higher). Open the […]

Tags: ,,,

June 24, 2016

GIC and Geographic Data View

Simulator’s Geographic Data View feature is uniquely suited for visualizing geomagnetically induced current (GIC) flows over a wide area. In the graphic below, each substation is depicted by a colored circle. The size of the circle is proportional to the GIC flowing through the neutral, while the color indicated whether GIC is flowing into or […]

Tags: ,,

August 18, 2015

GIC and Substation Coordinates for Line Taps

To properly perform geomagnetic induced current (GIC) analysis, substation geographic coordinates (longitude, latitude) must be provided for all substations that contain terminals of transmission lines for which a GIC-induced equivalent DC voltage is applied. Generally this includes all lines greater than the minimum length and minimum voltage specified on the GIC Analysis Form. The need for coordinates […]

Tags: ,,

March 26, 2015

Transformer GIC Thermal Response

This spreadsheet (revised November 3, 2017) includes sample formulas for calculating transformer winding and metallic parts hot spot temperatures as described in the NERC white papers Transformer Thermal Impact Assessment White Paper and Screening Criterion for Transformer Thermal Impact Assessment. It is provided with the following disclaimers: Input parameters in this spreadsheet are samples provided for illustration […]

Tags: ,,

February 9, 2015

Transformer Time-Series for NERC Benchmark GMD Event and Supplemental GMD Event

The following input files may be loaded to automatically simulate the time-series surface electric fields in the  NERC Benchmark Geomagnetic Disturbance Event (May 12, 2016) and Supplemental Event. Benchmark Event (updated November 2, 2017) Supplemental Event (updated June 8, 2018) From PowerWorld Simulator GIC, choose the “Spatially Uniform Time-Varying E-Field” Calculation Mode. Then point to the downloaded CSV file in the “Time-Varying […]

Tags: ,,

October 10, 2014

Example of Geomagnetic Induced Current (GIC) Calculations

Appendix II of the Application Guide: Computing Geomagnetically-Induced Current in the Bulk-Power System published by the North American Electric Reliability Corporation shows calculations of GIC currents and related quantities for a hypothetical power system with 6 buses and 3 substations. This system is available here for use in PowerWorld Simulator. These may be examined in the free […]

Tags: ,

July 18, 2014

GIC Modeling Data Requirements

Some general guides for substation and transformer inputs needed for GMD analysis may be found in the following links, with some specifics as they pertain to PowerWorld Simulator: A spreadsheet template (updated 2/14/2017) which describes the input data for substations and transformers needed to perform GIC analysis. (These are inputs that do not occur in FERC […]

Tags: ,

February 14, 2014