Competition Requires Transmission Capacity: The Case of the U.S. Northeast
The following cases were used to generate their respective figures in the July 2000 article in Regulation magazine entitled: “Competition Requires Transmission Capacity: The Case of the U.S. Northeast”. All files in the below list are *.zip files containing PowerWorld Binary (*.pwb) and PowerWorld Display (*.pwd) files. These cases may be viewed using PowerWorld Viewer, which is available here for free download. […]
Tags: Cases,Simulator,Technical Papers,Viewer
July 1, 2000
Edison Electric Institute Class, March 2000
Small sample cases and slides from Edison Electric Institute (EEI) class by Tom Overbye, March 2000.
Tags: Cases,Presentation
March 1, 2000
InfoVis 2000: New Methods for the Visualization of Electric Power System Information
Tom Overbye’s Slide Show from InfoVis 2000 in Salt Lake City, Utah.
Tags: Presentation,Simulator
January 1, 2000
PowerWorld OPF Training October 1999
PowerWorld Simulator OPF, by Tom Overbye, presented at PowerWorld Simulator Training Course in October, 1999. Includes slides of calculated LMPs for New York and New England.
Tags: Presentation,Simulator
October 1, 1999
Assessment of Transmission Constraint Costs: Northeast U.S. Case Study
T.J. Overbye, D. R. Hale, T. Leckey, J.D. Weber, “Assessment of Transmission Constraint Costs: Northeast U.S. Case Study” submitted for publication to IEEE Transactions on Power Systems on September 30, 1999.
Tags: Technical Papers
September 30, 1999
Individual welfare maximization in electricity markets including consumer and full transmission system modeling
J.D. Weber, “Individual welfare maximization in electricity markets including consumer and full transmission system modeling,” Ph.D. thesis, University of Illinois at Urbana-Champaign, Department of Electrical and Computer Engineering, September 1999.
Tags: Technical Papers
September 1, 1999
Actual PJM LMPs
Acutal PJM Locational Marginal Price Data as Shown in PowerWorld Simulator Contour Plot, several hours on July 19, 1999 by PowerWorld Corporation (several slides, 717 kB).
Tags: Presentation,Simulator
July 19, 1999
Market Power Evaluation in Power Systems with Congestion
Market Power Evaluation in Power Systems with Congestion, by Tom Overbye, presented at 1999 IEEE Summer Meeting.
Tags: Presentation,Simulator
June 29, 1999
How the Power Grid Behaves
How the Power Grid Behaves, by Tom Overbye, presented at 1999 April AAPG Meeting.
Tags: Presentation
April 1, 1999
Evaluating Market Power in Congested Power Systems
K.J. Patten, “Evaluating Market Power in Congested Power Systems,” M.S. thesis, University of Illinois at Urbana-Champaign, Department of Electrical and Computer Engineering, December 1998
Tags: Technical Papers
December 1, 1998
