Bug Fixes
- Available Transfer Capability (ATC) Tool: The ATC Multiple Scenario Results table is populated with information from the limiter with the lowest Trans Lim value from all limiters that have been iterated on. If none have been iterated on then it is populated from the limiter with the lowest Trans Lim value. It was possible if a reserve limit was hit during the initial part of the iterated process when all limiters are iterated on that the limiter chosen was the first one in the list and not necessarily the one with the lowest Trans Lim if none of the limits had been marked as being iterated on. This has been fixed.
- Available Transfer Capability (ATC) Tool: When attempting to get a failed contingency solution to solve using SOLUTIONFAIL actions, remaining SOLUTIONFAIL actions would not be applied if the last action made no changes. This has been fixed.