Features and Improvements
- Available Transfer Capability (ATC) Tool: With iterated ATC methods added two new Iteratively Found strings: YES_INFINITE and FULL_INFINITE. These indicate that the PTDF/OTDF have become too small in the process of iterating on an individual limiter, and the transfer limit is treated as infinite. This had previously been indicated by the Trans Lim value being set to a very large number, and now these new strings give another clearer indication of this. Additionally, the highlight color for these types of limiters are lighter versions of yellow and blue used to indicate YES and FULL limiters, respectively.
- Contingency Analysis Tool: Added script command CTGVerifyIteratedLinearActions that takes a single parameter, filename, for an input. This action will save a file that identifies which fields and conditional actions (remedial actions) are valid for use with the iterated linear analysis method for contingency and ATC analysis.
- Transient Stability: For some exciters added checking when E1=E2 and SE1 <> SE2 <> 0.
- Distributed Computation: When running distributed contingency analysis the Selected field for Contingency objects was being set to NO after the run. This has been fixed.