Features and Improvements
- Auxiliary Files (SCRIPT and DATA Sections): The AutoCalc variable with IG_AutoInsert_Options and IG_AutoInsert_Options_Value used with the InjectionGroupsAutoInsert script command was being used as the opposite value when used to set the AutoCalc field with PartPoint objects. This has been fixed. The legacy variable PPntUseFixedParFac was being used correctly. A new concise variable called UseFixedPartFact has been added that is the opposite of AutoCalc.
- Auxiliary Files (SCRIPT and DATA Sections): Added EnumerateDDLOnelines script command. This command creates a file that lists all of the oneline diagrams contained within an Areva/Alstom/GE DDL file.
- Auxiliary Files (SCRIPT and DATA Sections): The Selected field for ViolationCTG objects was not being set correctly. This has been fixed.
- Auxiliary Files (SCRIPT and DATA Sections): Fixed a bug that could cause an access violation when using the ImportDDLAsTranslation() script command.
- Transient Stability: When transferring the transient stability present state to the power flow for visualization, if a generator was configured to be on line-drop compenstation in the power flow the transferred state would appear with mismatches at the generator on line-drop compensation. This has been fixed.