Features and Improvements
- Auxiliary Files (SCRIPT and DATA Sections): Added column contour to the AUX format as a SUBDATA section on the DataGrid (string grid customization) object.
- Available Transfer Capability (ATC) Tool: When using iterated ATC methods the ramping is done relative to load and generator outputs in the base case so that generators will hit and back off limits consistently if transfer stepsizes change sign. When using injection groups as the source and sink it was possible that the ramping was being done relative to the total transfer already achieved rather than this base starting point. This could result in oscillatory behavior. This has been fixed.
- Transient Stability: Fixed a bug in which the reading a dyd file a certain dc branch wasn't loading the dynamic ecpdc model. Now this is corrected and the epcdc model is read into transient stability.
- Transient Stability: Fixed a bug with writing cmpldwg DGMBase parameter. When saving into dyd file and the load object DGMBase value is zero it was writing the load object DGMBase value as zero and not the transient model value.
- Transient Stability: Corrected UEL model MNLEX2. The other fields: Activation Status and PQSig values were being output incorrectly.