PV Curves Results: Track Limits
The Track Limits sub-tab is found on the PV Results tab of the PV Curves dialog. This page provides access to the results of tracking devices at limits that are determined during the PV analysis.
The page is divided into several additional sub-tabs for the different types of devices that can be tracked. Tables on each tab are similar in that they list all of the devices of that type that were tracked. For PV analysis, each column of the table is the transfer amount at which the device limits were checked. For PV analysis, device limits are only checked for base case conditions (i.e. no contingencies are applied). The results show where each element was located relative to its min/max limits during each step of the analysis using the indicators of Within Limits, Within Range, At Max, and At Min. To simplify the display and exclude those elements that were always within their limits during all steps of the process, check the box Filter out devices that never hit or backoff a limit during the PV run.