Generator Cost Models Display
The Generator Cost Models Display presents detailed cost information for each generator in the case, regardless of what type of cost curve has been entered for the generator. The Generator Cost Models Display is a class of
To show the generator piecewise linear and cubic cost model display, select Network > Generators > Cost Curves All from the Model Explorer.
By default, the generator records display contains the following fields:
Number, Name
Number and name of bus to which the generator is attached.
Area Name of Gen
Name of the area to which the generator belongs. The generator can be assigned to an area different than the area to which its terminal bus is assigned.
ID
Single character ID used to distinguish multiple generators at the same bus; ‘1’ by default.
Status
The Open / Closed status of the generator. This is a toggleable field.
AGC
Designates whether the generator’s real power output is governed by automatic generation control. If the AGC field is set to Yes, the generator is on automatic generation control (AGC). When a generator is on AGC, its real power output can be varied automatically. Usually the purpose for AGC is to keep the area interchange at a desired value. You can click on this field to toggle its value (except in Viewer). Please see Area Control for more details.
Gen MW
Current real power output of the generator.
Min MW
Minimum MW output of the generator.
Max MW
Maximum MW output of the generator.
Cost Model
The type of model this generator is currently using. Can be Cubic, Piecewise Linear or None.
IOA, IOB, IOC, IOD
Parameters used to model the cost characteristic of the generator. Please see
These fields will be disabled unless the Cost Model type is set to Cubic.
Fuel Cost
The fuel cost of the type of fuel for the generator.
Variable O&M
Operations and Maintenance costs for the generator.
This field will be disabled unless the Cost Model type is set to Cubic.
Fuel Type
An informational field that can be set to the type of fuel the generator uses.
Unit Type
An informational field that can be set to reflect the type of unit the generator is, such as combined cycle, steam, hydro, etc.
Cost Shift $/MWh, Cost Multiplier
The cost shift and cost multiplier allow you to easily apply a shift to the cost function for the purpose of assessing how variations in bids impact profit. The cost function is affected based on the following equation:
(Original Cost Function + Cost Shift) * Cost Multiplier
Fixed Cost
The fixed operating cost of the generator.
MWh Break x, MWh Price x
The remainder of the display is populated with MWh Break and MWh Price pairs. These pairs define the break points of the piecewise linear curve. The MWh Break value is a MW output value of the generator. The MWh Price value is the corresponding marginal cost of producing an additional MW of power at that MW output level. Therefore entering the break points of the piecewise linear curve in this manner defines the slopes of the next section of the curve, starting at the current MW Break point and up to but not including the next defined break point. The last MWh Break and MWh Price pair defined will define the marginal price of the unit from that break point location to the maximum output of the generator.
A requirement of the piecewise linear cost curve is that it must be convex, meaning the next MWh Price must be higher than the previous MWh Price.
These fields will be disabled unless the Cost Model type is set to Piecewise Linear.