Case Information Filterbar

Concept Link IconSee Also

 

On the Model Explorer, directly above the case information display is the Case Information Filterbar. Although the Filterbar is not shown by default on other case information displays not embedded in the Model Explorer, the Filterbar can be shown by right-clicking on the Case Information Toolbar and choosing Filterbar>Top or Filterbar>Bottom. The Filterbar is shown in the following image.

For some object types it is possible to filter based on data for a related object class instead of for the actual object class. For example, an Advanced Filter for a Bus may exist to only show buses with a Nominal Voltage larger than 138 kV. You may then want to use this filter on a case information display which shows generators. For object types which support this feature, the Filter By Dropdown and the Filter Type Dropdown will be available. For objects which do not support this, these dropdowns will not be visible.

 

Filter By Dropdown

This value will be either Advanced or Device. For more information about this setting see the Advanced Filtering Dialog help.

Filter Type Dropdown

This dropdown allows you to specify which class to base the filter on. For more information about this setting see the Advanced Filtering Dialog help.

List of Filters or Devices Dropdown

When the Filter By Dropdown is set to Advanced, this dropdown will contain a list of all the presently defined advanced filters for the object type specified in the Filter Type Dropdown.

When the Filter By Dropdown is set to Device, this dropdown will contain a list of all objects of the object type specified in the Filter Type Dropdown.

When clicking on this dropdown the appropriate list will be shown and by choosing an entry from this dropdown the respective advanced or device filter is applied to the case information display. Also, if the dropdown contains more than 1,000 entries in it, clicking on this dropdown will instead have the same effect as clicking on the Find... Button.

Find... Button

Click on this button to open the Advanced Filtering Dialog for the case information display.

Remove Button

Click this button to remove the Advanced Filter or Quick Filter from the present case information display. This does not delete an advanced filter definition, but only removes the reference to it from the active case information display. The filter can easily to reapplied after removing it. If you would like to permanently delete an Advanced Filter see Advanced Filtering.

Quick Filter Drop Down

Click this button to open a menu with options regarding defining a Quick Filter. There are methods of provide open the Quick Filter dialog, Clear the Quick Filter, change the Boolean logic, as well as quickly add a condition to the quick-filter using the column in which the cursor is currently set in the display. See the Quick Filter help for more details.