Line Field Options Dialog
This dialog can be opened by right-clicking on a line display field and choosing to open the Line Field Information Dialog while in run mode. If in edit mode this dialog will be opened simply by right-clicking on a line display field.
This dialog is used to view and modify the parameters associated with these fields.
Find…
If you do not know the exact line identifiers you are looking for, you can click this button to open the advanced search engine.
Near Bus Number
Bus associated with the near end of the object. All fields specifically listed in the Type of Field, i.e. NOT the fields in Select a Field, display values calculated at the near bus end. When inserting fields graphically, this field is automatically set to the closest bus on the oneline.
Far Bus Number
Bus associated with the far end of the object.
Circuit
Two-character identifier used to distinguish between multiple lines or transformers joining the same two buses. Default is ‘1’.
Total Digits in Fields
Total number of digits to show in the field.
Digits to Right of Decimal
Number of digits to show to the right of the decimal point.
Delta Per Mouse Click
Only used with the MVA Limit field type. Specifying a nonzero value for this field equips the MVA Limit field with an integrated spin button that can be clicked to increment or decrement the MVA Limit by the amount of the Delta Per Mouse Click value.
Field Value
The current value of the field being displayed.
Field Prefix
A prefix that can be specified and displayed with the selected value.
Rotation Angle in Degrees
The angle at which the text will appear on the diagram.
Anchored
If this checkbox is checked, the line analog is anchored to its associated line.
Include Suffix
If this checkbox is checked, the corresponding field units will be displayed after the current value. Otherwise, only the value without units will be shown.
Type of Field
Used to determine the type of line field to show. The following choices are available:
MW Flow
MW flow into the line or transformer at the near bus.
Mvar Flow
Mvar flow into the line or transformer at the near bus.
MVA Flow
Magnitude of MVA flow into the line or transformer at the near bus.
Amp Flow
Magnitude of amps into the line at the near bus.
MW Losses
Real power losses on the line or transformer in MW.
Mvar Losses
Reactive power losses on the line or transformer in Mvar.
MVA Limit
MVA limit for the line or transformer. This limit is determined based on the line's Limit Set and the option with that Limit Set that specifies which rating set to use for the Normal Rating Set. Delta per Mouse Click can be specified to show a spin button next to this value that can be used for changing it directly from the oneline.
Select a Field
Choose from any of the available line fields. Use the Find Field button to open a dialog from which the field can be selected.
Checking the Draw Sparkline checkbox will display a sparkline instead of a field value on the oneline and list only those fields that are available for representation as a sparkline.
Select OK to save changes and close the dialog or Cancel to close the dialog without saving your changes.