Over Excitation Limiter Model: BASOEL2
Added in Version 24, build on August 5, 2025
To be documented.
Model Equations and/or Block Diagrams
Parameters:
| OELFlag | OEL Status. 0=disable; <>0=enable |
| VHzFlag | V/Hz Status. 0=disable; <>0=enable |
| OELIn | OEL input. 0=Efd; 1=Ifd; 2=Vfe |
| TRoel | [seconds] OEL regulator input filter time constant |
| Kp | [pu] OEL regulator proportional gain |
| Ki | [pu] OEL regulator integral gain |
| OEL1 | [pu] Short-time allowed overload |
| OET1 | [seconds] Short-time overload time (normally zero) |
| OEL2 | [pu] Medium-time allowed overload |
| OET2 | [seconds] Medium-time overload time |
| OEL3 | [pu] Continuous limit |
| OET3 | [seconds] Continuous limit time |
| TRVHz | [seconds] V/Hz limiter regulator input filter time constant |
| KVHz | [pu] V/Hz limiter gain |
| VHzmin | [pu] V/Hz limiter minimum input |