Transformer Field Options Dialog

Concept Link IconSee Also

 

Transformer field display objects are used to show field values specific to transformers on onelines. Use Line Fields to show fields generic to transformers and transmission lines, such as the flow of power through the device.

This dialog can be opened by right-clicking on a transformer display field and choosing to open the Transformer Field Information Dialog while in run mode. If in edit mode this dialog will be opened simply by right-clicking on a transformer display field.

The transformer field options dialog is used to view and modify the parameters associated with transformer-specific fields.

 

Near Bus Number

Bus associated with the near end of the transformer.

Far Bus Number

Bus associated with the far end of the transformer.

Circuit

Two-character identifier used to distinguish between transformers joining the same two buses. Default is '1'.

Find…

If you do not know the exact transformer you are looking for, you can click this button to open the advanced search engine.

Total Digits in Field

Total number of digits to show in the field.

Digits to Right of Decimal

Number of digits to show to the right of the decimal point.

Delta per Mouse Click

This value is used only with the Off-nominal Tap Ratio and Phase Shift Angle field types. When there is a nonzero entry in this field, and the field type is valid, a spin button is shown to the right of the zone field. When the up spin button is clicked, the field value is increased by this number; when the down button is clicked, the field value is decreased by this amount.

Field Value

Shows the current output for the transformer field. Whenever you change the Type of Field selection, this field is updated.

Field Prefix

A prefix that can be specified and displayed with the selected value.

Rotation Angle in Degrees

The angle at which the text is to appear on the oneline diagram.

Anchored

When checked, the text field will move with the transformer if the transformer is moved on the oneline diagram.

Include Suffix

If this checkbox is checked, the corresponding field units will be displayed after the current value. Otherwise, only the value without units will be shown.

Type of Field

Designates the type of transformer field to show. The following choices are available:

Off-nominal Tap Ratio 

Actual tap ratio on the system base. Delta per Mouse Click can be specified to show a spin button next to this value that can be used for changing it directly from the oneline.

Phase Shift Angle 

Actual phase shift in degrees. Delta per Mouse Click can be specified to show a spin button next to this value that can be used for changing it directly from the oneline.

Off-nominal Tap Position 

Tap position in steps, usually ranging from -16 to +16.

Automatic Control Status 

The status of the control for the transformer. While in run mode left clicking on this field will toggle the automatic control status of the transformer.

 

Select OK to save changes and close the dialog or Cancel to close dialog without saving your changes.