Pie Chart / Gauge Style Dialog - Standard Parameters Tab
Normal Scalar, Normal Fill Color
These are the standard, pre-warning scaling factor and fill color for pie chart/gauges. To change the color, click on the color to open the Color dialog.
Font Color
Font color of the text displayed in the pie chart/gauge. To change the color, click on the color to open the Color dialog.
Border Width
Width of any border portion of the pie chart/gauge. The border of a pie chart encloses the entire pie chart as well as the filled portion of the pie chart. The border of a gauge encloses the entire gauge. The border width also impacts the width of the lines marking the limits and deadband on the gauge.
Border Color
Color of any border portion of the pie chart/gauge. The border of a pie chart encloses the entire pie chart as well as the filled portion of the pie chart. The border of a gauge encloses the entire gauge. The border color also is the color used for the lines marking the limits and deadband on the gauge. To change the color, click on the color to open the Color dialog.
Border Color Same as Fill Color
When checked, the border color will be the same color as the fill color and the color selected in the Border Color will be ignored.
Background Color
The drop-down box allows selection of three options for the background color: Oneline Background, Specific Color, and Clear. Oneline Background will color the pie chart/gauge background the same color as the selected background color for the oneline. Specific Color will allow the selection of a user specified color. To specify a color, click the box to the right of the drop-down to open the Color dialog. The Clear option will not use a background color and objects underneath the pie/chart gauge will be visible through the unfilled portions of the pie chart/gauge.
Relative Font Size
Modify the track bar to adjust the size of the font relative to the size of the pie chart/gauge.
Max Zoom Percent for Full Resize
Pie chart/gauges dynamically resize when zooming in and out on oneline diagrams. A limit can be placed on the point at which the pie chart/gauges resize when zooming in by setting a zoom level in this field. This helps prevent the pie chart/gauges from getting so large that they occupy the entire screen.
Warning/Limit Scalars and Colors
The table in this section allows the definition of different settings for pie chart/gauge size and fill color based on the percent value represented by the pie chart/gauge. Points can be added or removed from this table by right-clicking in the table and using the Insert and Delete options from the popup menu.
To modify the Percent and size Scalar for a record in the table, click on the value in the cell and type in a new value. To change the color associated with the percent value, double click in the Color cell to open the Color dialog.
Use Discrete Map
When checked, discrete colors will be used for the pie chart/gauges based on the colors specified in the table. Otherwise, colors will be blended if the percentage represented in the pie chart/gauge falls between percentages defined in the table.