DC Line Field Options Dialog

Concept Link IconSee Also

 

DC line field display objects are used to show different values associated with DC lines on onelines.

This dialog can be opened by right-clicking on a dc line display field and choosing to open the DC Line Field Information Dialog while in run mode. If in edit mode this dialog will be opened simply by right-clicking on a dc line display field.

This dialog is used to view and modify the parameters associated with these fields.

 

Find…

If you do not know the exact line identifiers you are looking for, you can click this button to open the advanced search engine.

Near Bus Number

Bus associated with the near end of the object. All fields display values calculated at the near bus end. When inserting fields graphically, this field is automatically set to the closest bus on the oneline.

Far Bus Number

Bus associated with the far end of the object.

Circuit

Two-character identifier used to distinguish between multiple dc lines joining the same two buses. Default is ‘1’.

Total Digits in Fields

Total number of digits to show in the field.

Digits to Right of Decimal

Number of digits to show to the right of the decimal point.

Delta Per Mouse Click

This option is not currently used with any of the available fields.

Field Value

The current value of the field being displayed.

Field Prefix

A prefix that can be specified and displayed with the selected value.

Rotation Angle in Degrees

The angle at which the text will appear on the diagram.

Anchored

If checked, the line analog is anchored to its associated line.

Include Suffix

If the Include Suffix checkbox is checked, the corresponding field units will be displayed after the current value. Otherwise, only the value without units will be shown.

Type of Field

Used to determine the type of line field to show. The following choices are available:

Control Mode

Control model for the DC line; see DC Transmission Line dialog

Setpoint Magnitude

Set point magnitude for the DC line; see DC Transmission Line dialog

Setpoint Location

Set point location for the DC line; see DC Transmission Line dialog

Set Voltage

Set voltage for the DC line; see DC Transmission Line dialog

MW Flow 

MW flow into the DC line at the near bus; see DC Transmission Line dialog

Mvar Flow 

Mvar flow into the DC line at the near bus; see DC Transmission Line dialog

Select a Field 

Choose from any of the available dc line fields. Use the Find Field button to open a dialog from which the field can be selected.

 

Select OK to save changes and close the dialog or Cancel to close the dialog without saving your changes.