Home 

>>

Support

>>

Retriever Version 14 Patch Description

 
 
 

Customer Support

Support Home

Support FAQ

Changing the License Key

Simulator Tips

  Example Auxiliary Files

  Example SimAuto Files

Video Capture

Educator's Corner

Contact PowerWorld

 
 

 


What's in the Retriever 14 Patch?

Note: Retriever is built on top of the Simulator Product Line. As a result, changes made to Simulator will affect Retriever as well. For a list of changes made to Simulator 14 see the Simulator 14 patch description. The changes listed below are of particular importance to Retriever.

The PowerWorld Retriever 14 patch addresses any problems found in Retriever 14 following its official release in March 2009. New features are also added in the patch as appropriate.

The patch was first introduced on March 16, 2009.

The Retriever patch was last updated January 6, 2012.

Click here to go to the patch download page.

New Features/Minor Improvements:

  • (April 8, 2009) Added ability to view alias subscriptions by the type of object subscribed to. This then allow the viewing of all fields associated with the subscriber as well.
  • (May 27, 2009) Added the ability for alias subscriptions to return string results.
  • (June 4, 2009) Also added a field to give the subscription priority. This priority accurately reflects the order in which values will be chosen if available from a data source. This is only relavent if multiple aliases are subscribed to the same field.
  • (September 29, 2009) When reading a text file data source and encountering a null character, the read of the file was aborted after the null character. This has been modified to skip the invalid null characters and properly read the data source.

Bug Fixes:

  • (April 28, 2009) Fixed access violation which occurred having the Retriever Control panel open while opening a new case.
  • (May 6, 2009) In the Image Exporter, the ability to export images to ONLY a non time-stamped file name was added.
  • (May 20, 2009) In the Image Exporter was not properly exporting images when Emphasis was being used. This has been fixed.
  • (June 4, 2009) Fixed a bug that occurred when reading an aliased data value from a data source that wasn't declared as actually containing that alias. This caused a 0 to be read and marked at up to date, which was not correct.
  • (July 23, 2009) Fixed a problem where the load field would grab the bus' aggregated load value and display that during real-time mode.
  • (September 11, 2009) Fixed an error which would not allow the Custom String values for Branch objects to be seen in Real Time mode.
  • (September 29, 2009) Fixed a problem where line status would appear as the number "1" or "0" in real-time mode instead of "Closed" or "Open".
  • (September 29, 2009) Fixed potential issue with branches appearing as dashed to signify open when they were not actually open. (related to previous bug fix).
  • (November 2, 2009) Circuit breaker symbols were being drawn as "open" if they were closed, but de-energized. This has been fixed so that circuit breakers continue being displayed as closed even when they are de-energized.
  • (December 1, 2009) Fixed the model population so that voltages are populated first, then statuses, then voltages are propagated within superbuses and then finally the remaining real-time values are populated into the model. This ensures that the superbuses are set properly according to statuses before the topology is used to set voltages within superbuses. This wasn't guaranteed previously.
  • (December 1, 2009) Fixed the model population so that branch MW and Mvar flows are automatically calculated after model population.
  • (December 22, 2009) Fixed Model Population error related to changes on December 1. Error was related to incorrectly determining which buses were disconnected.
  • (April 27, 2010) Force pie charts to be shown in real-time mode if max flow checkbox is checked in oneline options and a subscription exists on *either* end of the transmission line.
  • (April 29, 2010) Calculated Fields were not properly treating blank unretrieved values. Unretrieved values were alwasy considered zero even if the calculated field specified they should be ignored. This has been fixed.
  • (July 16, 2010) Changing the status of a branch while in Run Mode was not working properly in Retriever.
  • (September 28, 2010) Fixing bug with flow arrow size calculation when subscribing to limits.
  • (October 15, 2010) Made changes so that Retriever doesn't automatically populate subscription limits with limits from the model since subscription limits override limits from the model.